PENDANT CABLES

H05VVH6 – F / HO7VVH6 – F
May 15, 2020
VG 95218/PART 60 (MGSGO)
May 18, 2020

PENDANT CABLES

Certificates:

Application

These pendant cables are used as control or feeder cables in lifts and hoists. The two steel load bearing elements can be detached without damaging the outer sheath and fixed independently from the cable gland The cable offers high flexibility at lower temperatures due to the quality of material used in the construction. The two special torsion-free steel supporting elements found parallel on both sides of the outer jacket are. These cables are not suitable for drum reeling installations.

Download Pdf

CONDUCTORS : Electrolytic, stranded, plain annealed copper wire Class 6 according to IEC 60228
INSULATION : Cross linked polyethylene compound (XLPE) or PVC on request
CORE IDENTIFICATION : Black cores with white numbers
LAY UP SUSPENSION : Cores laid up in concentric layers , over lay up textile tape wrapped
SUPPORT : Galvanized steel wire ropes at both sides
OUTER SHEATH : Special PVC Compound
COLOR : Black
CONSTRUCTION : Generally to IEC 227 and VDE 0295
FLAME RETARDANT : IEC 60332-1
OIL RESISTANT : HD/EN/IEC 60811-2-1, DIN VDE 0473 part 811-2-1
RATED VOLTAGE : 300 / 500 V
AC TEST VOLTAGE : 2000 V
MIN BENDING RADIUS : 10 x D (fixed application) 20 x D (mobile application)
CURRENT CARRYİNG CAPACITY : According to DIN VDE 0298-4
WORKING TEMPATURE :
FIXED INSTALLATİON : – 40 °C up to + 70 °C
MOBILE OPERATION : – 25 °C up to + 70 °C
MAX. TENSILE LOAD ON CONDUCTOR : 15 N / mm2
MAX. SUSPENDED HEIGHT : 80 meters
PULLING FORCE : 2100 N for each steel core
No. Conductors X Cross Section (mm2) Outer Diameter Min. – Max. (mm) Cable Weight (kg / km)
5 x 1,510,0 x 20,0 ± % 5210
6 x 1,510,3 x 19,0 ± % 5255
8 x 1,512,5 x 22,0 ± % 5300
10 x 1,512,4 x 21,0 ± % 5330
12 x 1,513,0 x 23,0 ± % 5350
14 x 1,513,4 x 22,0 ± % 5405
16 x 1,515,5 x 25,5 ± % 5440
20 x 1,516,5 x 27,5 ± % 5525
24 x 1,519,9 x 29,5 ± % 5575
 
Seabright SA