ÜNFLEX SPREADER REEL PUR – HF
For use as vertical reeling cable under high mechanical stresses, torsion, tension and torque. Mainly used for spreader reeling application A strength member has been integrated to increase tensile load, acceleration and speed. The special polyurethane compound jacket offers a very good protection against hydrolysis,solvents,alkalines and oils.
Download Pdf
Download Pdf
CONDUCTOR : Electrolytic, plain annealed copper wire Class 5 according to IEC 60228
INSULATION : All cores are insulated with halogen free compound, based on polyester. In need cores are wrapped by PTFE to increase the abrasion resistivity.
CORE IDENTIFICATION : Up to 5 cores: colored in accordance with DIN VDE 0293-308; From 6 cores: white cores with black numbers
LAY UP : Central Aramid strength member, cores laid up in concentric layers with shorth length of lay
INNER SHEATH : Halogen Free, flame retardant Polyurethane compound
REINFORCEMENT : Anti-twisting element – Aramid yarns braiding
OUTHER SHEATH : Halogen Free, flame retardant Polyurethane compound
COLOR : Yellow, black or orange
INSULATION : All cores are insulated with halogen free compound, based on polyester. In need cores are wrapped by PTFE to increase the abrasion resistivity.
CORE IDENTIFICATION : Up to 5 cores: colored in accordance with DIN VDE 0293-308; From 6 cores: white cores with black numbers
LAY UP : Central Aramid strength member, cores laid up in concentric layers with shorth length of lay
INNER SHEATH : Halogen Free, flame retardant Polyurethane compound
REINFORCEMENT : Anti-twisting element – Aramid yarns braiding
OUTHER SHEATH : Halogen Free, flame retardant Polyurethane compound
COLOR : Yellow, black or orange
CONSTRUCTION : Generally to IEC 60502 & VDE 0250
ELECTRICAL TESTS : DIN VDE 0472-501, 502, 503, 508
NON-ELECTRICAL TESTS : DIN VDE 0472-401, 402, 602, 303, 615
GENERAL REQUIREMENTS : DIN VDE 0250-1 and IEC 60502
FLAME RETARDANT : IEC 60332-1
OİL RESISTANT : HD/EN/IEC 60811-2-1, DIN VDE 0473-811-2-1
ELECTRICAL TESTS : DIN VDE 0472-501, 502, 503, 508
NON-ELECTRICAL TESTS : DIN VDE 0472-401, 402, 602, 303, 615
GENERAL REQUIREMENTS : DIN VDE 0250-1 and IEC 60502
FLAME RETARDANT : IEC 60332-1
OİL RESISTANT : HD/EN/IEC 60811-2-1, DIN VDE 0473-811-2-1
RATED VOLTAGE : 0,6 / 1 kV
MAX. OPERATING AC VOLTAGE : 0,7 / 1.2 kV
MAX. OPERATING DC VOLTAGE : 0,9 / 1.8 kV
AC TEST VOLTAGE : 3,5 kV
MİN BENDING RADIUS : 6 x D (fixed application) 8 x D (mobile applications)
CURRENT CARRYING CAPACITIES : According to DIN VDE 0298-4
WORKİNG TEMPERATURE
FIXED : – 50 °C up to + 90 °C
MOBILE : – 40 °C up to + 90 °C
CONDUCTOR OPERATING TEMPATURE : + 90 °C
CONDUCTOR SHORT CIRCUIT :
TEMPATURE : + 250 °C
MAX. TENSILE LOAD ON CONDUCTOR : 30 N / mmÇ
MAX. TORSION : ±25º/m
TRAVEL SPEED
IN FESTOON SYSTEMS : up to 240 m/min
IN REELING APPLICATIONS : up to 240 m / min. horizantal up to 180 N /mm vertical
MAX. OPERATING AC VOLTAGE : 0,7 / 1.2 kV
MAX. OPERATING DC VOLTAGE : 0,9 / 1.8 kV
AC TEST VOLTAGE : 3,5 kV
MİN BENDING RADIUS : 6 x D (fixed application) 8 x D (mobile applications)
CURRENT CARRYING CAPACITIES : According to DIN VDE 0298-4
WORKİNG TEMPERATURE
FIXED : – 50 °C up to + 90 °C
MOBILE : – 40 °C up to + 90 °C
CONDUCTOR OPERATING TEMPATURE : + 90 °C
CONDUCTOR SHORT CIRCUIT :
TEMPATURE : + 250 °C
MAX. TENSILE LOAD ON CONDUCTOR : 30 N / mmÇ
MAX. TORSION : ±25º/m
TRAVEL SPEED
IN FESTOON SYSTEMS : up to 240 m/min
IN REELING APPLICATIONS : up to 240 m / min. horizantal up to 180 N /mm vertical
No. Conductors X Cross Section (mm2) | Outer Diameter Min. – Max. (mm) | Cable Weight (kg / km) |
---|---|---|
18 x 2,5 | 22,0 – 26,0 | 1100 |
24 x 2,5 | 26,4 – 29,4 | 1400 |
30 x 2,5 (5 x 6 x2,5) | 30,2 – 34,2 | 1600 |
36 x 2,5 (6 x 6 x2,5) | 34,7 – 38,5 | 2080 |
36 x 2,5 | 30,2 – 33,0 | 1850 |
42 x 2,5 (7 x 6 x2,5) | 37,8 – 41,8 | 2280 |
44 x 2,5 | 32,5 – 35,5 | 1950 |
8 x (6 x 2,5) | 42,7 – 45,1 | 2620 |
54 x 2,5 (9 x 6 x 2,5) | 43,8 – 48,8 | 2800 |